[AR] Re: Quick disconnects...

  • From: Lars Osborne <lars.osborne@xxxxxxxxx>
  • To: Arocket List <arocket@xxxxxxxxxxxxx>
  • Date: Thu, 6 Dec 2018 09:57:28 -0800

More on this topic, can anyone recommend a quick disconnect which is
electrically actuated?
Thanks,
Lars Osborne


On Wed, Dec 5, 2018 at 9:14 AM John Dom <johndom@xxxxxxxxx> wrote:

Swagelok used to have many sizes of these 20 years ago.

John



*From:* arocket-bounce@xxxxxxxxxxxxx [mailto:arocket-bounce@xxxxxxxxxxxxx]
*On Behalf Of *Paul Breed
*Sent:* dinsdag 13 november 2018 22:21
*To:* arocket
*Subject:* [AR] Re: Quick disconnects...



The only problem is that they only come in one size, and one color, so
getting fuel and oxidizer lines swapped is possible....

:-(





On Tue, Nov 13, 2018 at 11:10 AM Paul Breed <paul@xxxxxxxxxx> wrote:



Actuate meaning "powered", spring loaded closed on release might or might
not be actuated depending on your definition...

I even drew up one QD with an external motor that screwed a plug into the
line...







On Tue, Nov 13, 2018 at 11:08 AM Norman Yarvin <yarvin@xxxxxxxxxxxx>
wrote:

On Tue, Nov 13, 2018 at 08:32:53AM -0800, Paul Breed wrote:

Most of the QD designs described here have a common feature, a check
valve.
I want to be able to do remote fill and drain like the big boys, so it has
to flow both directions....
and I don't want to add the weight of an actuated valve on the rocket
side.

Hmm, no check valve, and no actuated valve in the rocket... doesn't
that rule out every possible solution?

Maybe if you had a check valve for filling, and another orifice with
something like a burst disk that you could pierce from the outside for
draining?  Or just one orifice, and a check valve bypassing the burst
disk?


Other related posts: