[AR] Re: Regarding Hybrid Rocket Feed System Design

  • From: roxanna Mason <rocketmaster.ken@xxxxxxxxx>
  • To: arocket@xxxxxxxxxxxxx
  • Date: Mon, 4 Jan 2021 10:42:46 -0800

A health purge will do wonders. Have a regulator set maybe 5-10% below your
Pc with a check valve and 2x sol. valve between the reg and your motor
When you fire the motor energize the 2x sol. valve. purge gas will not flow
against chamber pressure higher than the purge reg set point. At end of
burn once the motor Pc drops it hands off to the purge. You get an instant
transition from Pc to purge, works great.
Dip tube? We're having a similar requirement on our 1.5KLbF LOx/Kero
rocket. I proposed a swagelok fitting with the dip tube slid down to the
desired liquid level then swage the tube. If a level change is needed
either cut the tube for a higher level or change out to a new swage/tube
assembly. You can also use brass hardware store compression fittings for
low budget easy access supply.
Not sure what your other question meant with a reg ball valve and nitrous
but be careful with the nitrous, don't let it cavitate or experience high
turbulence in a duct or get contaminated. Nitrous killed my friend and
colleague at Scaled Composites in 2010 along with two others.
Good luck,

Ken

On Mon, Jan 4, 2021 at 8:06 AM elias Aoubala <eliaslina88@xxxxxxxxxxxxx>
wrote:

Hey Guys,



A while back I started a thread here about initially designing my feed
system for a Hybrid Nitrous Oxide- HTPB engine. I think I’ve finally come
to final possible design and I wanted to post it here to get some opinions
from others on the design.



Overall I had a few questions I wanted to voice about the current design
of the feed system I have. Firstly My question is as to how do I prevent a
backflow of combustion flames through the injector line once it is shut off
after ignition. My first Idea was to implement another Flame back Arrestor
and/or have flame back arrestors on each line(main and ignitor)- however I
think there might be another solution which I am trying to figure out.



For the purge/fill vent (which I intend to use so I can use a dip tube on
my fill tank instead of gravity filling), I was initially thinking to put
it at the 4 way fitting above the tank which would simplify the tank design
significantly however I was thinking this would just lead to the liquid
flow to just exit thought the 4 way fitting to atmosphere instead of
actually entering the tank. Im not so sure about the design decision so I
would love to here thoughts about it.



Regarding the actual Dip tube for my fill tank- I’m getting my tank bought
from a third party and I wanted to know is their somewhat of a universal
method of building a dip-tube (or generally how do you build a dip tube for
third party tanks) and how do I do it (no experience with dip tube design).



Another point Id like to mention is the positioning of the actual back up
regulator, would I require anymore regulators for use between the actual
automated ball valves for Nitrous Oxide?



As you clearly can see from this post, I am still new to this so any
help/advice at all would be very much appreciated given how confusing this
feed system stuff can get and I really do appreciate the amount of help you
guys have given me already.



Many Thanks again,

Elias





Other related posts: