I'd be inclined to look at the flow temperature at a number of points across the cat-pack exit. Dunno how hard it is to find thermocouples that'll survive in an oxy-steam mix that hot, mind - if that's an impracticality, then an indirect temp measurement at the exit might serve.

On 12/18/2015 11:53 AM, Monroe L. King Jr. wrote:

Sensing combustion is a bit difficult but using peroxide it occurs to
me it might be more possible to sense the catalyzation completeness in
an easier way?

Any thoughts on how that might be accomplished?