On Sun, 28 Nov 2010 21:58:49 +0100
David Adler <david.jo.adler@xxxxxxxxx> wrote:
On Sun, Nov 28, 2010 at 8:41 AM, cal wrote:
yoshimi-0.062-pre5
the elusive filter and envelope controllers now appear to reaching the right
place - whether they're tweaking the right synth internals is yet to be
confirmed. Filter depth seemed about right.
My test results so far:
LFO and Filter parameters are fine.
Just display of the ADsynth Filter Envelope curve
seems corrupted since 0.062-pre3.
In more detail:
91 part effect 1 volume
92 part effect 2 volume
93 part effect 3 volume
nothing happens, but I never understood the effects section of zyn/yoshimi
all too well, so I might be wrong here.
102 ADsynth Filter Categorynothing happens
103 ADsynth Filter Typenothing again
104 Set kit item number for ADsynth Filter controlssegfault :( - I didn't repeat testing this one
105 ADsynth Filter LFO Frequencyworks
106 ADsynth Filter LFO Depthworks
107 ADsynth Filter LFO Startworks
108 ADsynth Filter LFO Delayworks
109 ADsynth Filter Envelope Startworks
110 ADsynth Filter Envelope Attackworks
111 ADsynth Filter Envelope Decay Valueworks
112 ADsynth Filter Envelope Decay Timeworks
113 ADsynth Filter Envelope Release Timeworks, but mixed up (in this list probably) - it's value
114 ADsynth Filter Envelope Release Valueworks, but mixed up (in this list probably) - it's time
take 2 on the segfault(s) during gui control of effects parameters;confirmed, they're gone!
(by the way, they only occurred on my 32 bit machine)
greetings,
d