[AR] Re: Swagelok and LOX

  • From: "Anthony Cesaroni" <anthony@xxxxxxxxxxx>
  • To: <arocket@xxxxxxxxxxxxx>
  • Date: Sun, 29 Mar 2020 18:34:54 -0400

Recognize my co-driver? I brought him out of retirement after he nearly killed 
himself so that proves I can at least sell something.

 



 

Anthony J. Cesaroni

President/CEO

Cesaroni Technology/Cesaroni Aerospace

 <http://www.cesaronitech.com/http://www.cesaronitech.com/

(941) 360-3100 x101 Sarasota

(905) 887-2370 x222 Toronto

 

From: arocket-bounce@xxxxxxxxxxxxx <arocket-bounce@xxxxxxxxxxxxx> On Behalf Of 
Anthony Cesaroni
Sent: Sunday, March 29, 2020 6:27 PM
To: arocket@xxxxxxxxxxxxx
Subject: [AR] Re: Swagelok and LOX

 

I did. Same test too. ðŸ˜Š

 

Anthony J. Cesaroni

President/CEO

Cesaroni Technology/Cesaroni Aerospace

 <http://www.cesaronitech.com/http://www.cesaronitech.com/

(941) 360-3100 x101 Sarasota

(905) 887-2370 x222 Toronto

 

From: arocket-bounce@xxxxxxxxxxxxx <mailto:arocket-bounce@xxxxxxxxxxxxx>  
<arocket-bounce@xxxxxxxxxxxxx <mailto:arocket-bounce@xxxxxxxxxxxxx> > On Behalf 
Of William Claybaugh
Sent: Sunday, March 29, 2020 5:52 PM
To: arocket@xxxxxxxxxxxxx <mailto:arocket@xxxxxxxxxxxxx
Subject: [AR] Re: Swagelok and LOX

 

Anthony:

 

You should have been a race car driver.

 

Bill

 

On Sun, Mar 29, 2020 at 3:50 PM Anthony Cesaroni <anthony@xxxxxxxxxxx 
<mailto:anthony@xxxxxxxxxxx> > wrote:

When I was young, I tried to get a job in sales at Swagelok. They made me write 
a test to determine if I would make a good salesman. I flunked it.

 

Anthony J. Cesaroni

President/CEO

Cesaroni Technology/Cesaroni Aerospace

 <http://www.cesaronitech.com/http://www.cesaronitech.com/

(941) 360-3100 x101 Sarasota

(905) 887-2370 x222 Toronto

 

From: arocket-bounce@xxxxxxxxxxxxx <mailto:arocket-bounce@xxxxxxxxxxxxx>  
<arocket-bounce@xxxxxxxxxxxxx <mailto:arocket-bounce@xxxxxxxxxxxxx> > On Behalf 
Of Michael Clive
Sent: Saturday, March 28, 2020 11:35 PM
To: arocket@xxxxxxxxxxxxx <mailto:arocket@xxxxxxxxxxxxx
Subject: [AR] Re: Swagelok and LOX

 

To continue on Ben's vibe: 

 

Swagelok is the best brand for compression type fittings. Parker etc are 
slightly worse in terms of quality control, from my experience. Surface 
finishes are not as nice, plating is worse. Swagelok also is expensive but very 
responsive and kind. Their sales reps will do anything for you, if you buy 
enough. If not, Ebay will get you everything you need. 

 

NEVER mix and match a parker fitting to a swage body, or a parker body to a 
swage fitting. They claim they are interchangeable, but they can have minor 
variations in geometry and thread form that can gall stuff up or generally make 
your day worse.

 

McMaster compression fittings are Parkers. They are okay, but nothing beats the 
real thing. 

 

Swages above 3/4" become a huge pain in the ass and you need a hydraulic 
preswaging tool and a second bank account for fittings at or above 1". 

 

Swages are excellent, but you need to be really experienced with them. There 
are no torque specs. there are no torque specs. You torque them down until a 
certain displacement is met. You then always reseat them with the tiniest bit 
more oomf. If you don't have a calibrated arm, you will overswage if you ever 
reinstall, and it will leak, and you will have to pull the tube and replace it. 
There is no spec for this, it's just a feeling you develop after doing a few 
hundred of them. 

 

Big super obvious one that bit me when I was green: Don't swage a brass fitting 
on a stainless tube, or a stainless fitting on an inco tube. You can swage 
stainless on brass or inco on stainless, but always move down the strength 
chain. Why? The brass just won't bite the steel tube and it will 'splode. I had 
it happen on a 1/2" air line and it was loud and very embarrassing. 

 

And yeah, if you are a rocket person on this list and are working at 20ksi, 
good job on gettiing your phase 3 in-space propulsion contract from $GOVBUCKS. 
Looking forward to your launch.

 

My post-apocalypse profession is going to be as a plumber. 

 

 

On Sat, Mar 28, 2020 at 5:34 PM Ben Brockert <wikkit@xxxxxxxxx 
<mailto:wikkit@xxxxxxxxx> > wrote:

Ok, I'll backtrack to say that for 1/4" and smaller, higher pressures
are likely to be fine *if* you are swaging correctly and using normal
hardness tubing. The forces are not as crazy. But still, the advantage
of "cone and thread" and AN fittings is that if they are not tightened
they just leak, rather than having the tube go shooting out of the
fitting like an un- or under-swaged tube.

The Swagelok FK medium pressure system in half inch and larger with
thicker and harder tubing is trouble waiting to happen. I've seen it
go off twice, it's very violent and loud. Fortunately in neither case
was anyone injured.

And for folks new to this, "medium pressure" and "high pressure" are
terms of art for specific fitting systems, where medium is up to
20,000 psi and high is up to 60,000. Most rocketeers will never get
into medium pressure, and the highest you'll ever see is a 6000 psi
bottle that can be worked with using normal AN fittings.

And "Swagelok" is a company and a brand, but generally people use it
specifically to mean two ferrule compression fittings in the
Swagelok/Yor-Lok/A-lok line.

On Sat, Mar 28, 2020 at 2:55 PM Michael Clive <zeinin@xxxxxxxxx 
<mailto:zeinin@xxxxxxxxx> > wrote:


However, to follow up with Ben:

Medium, high pressure and UHP fittings are PHENOMENAL. If you do them right 
(cone-and-thread fittings), they never, ever leak. And they are very 
repeatable. Not good for vibe, but for test stands, they are great! Maximator 
makes the best tools for them. Peter Duffy at High Pressure Technologies is 
about the best sales guy you will ever talk to, and he will sell you anything 
you need for 10k+ work. Tubes, fittings, valves, anything.
I agree with Ben on not using bite type fittings EVER for above 10k work. 
Cone on thread is the best!

On Fri, Mar 27, 2020 at 8:55 PM Ben Brockert <wikkit@xxxxxxxxx 
<mailto:wikkit@xxxxxxxxx> > wrote:

I kinda hate Swagelok fittings over 3/4". They just suck to get leak
tight. 1/4" and 1/8" swagelok fittings are great, they are perfectly
suited to the task. Work fine with LOX. Follow the assembly
instructions! Buy a preswaging die if you use them a lot. 1/4"
swagelok fittings are the easiest way to build weird assemblies like
temperature/pressure ports in pipes or coaxial heat exchangers. And
work well for things like gauge boxes, test benches, etc. They're also
called "instrumentation fittings" and that is a good description of
what they are good for.

They are not great with vibe. Well suited to ground equipment, less so
to flight.

If you use them with peroxide the nuts should be processed in acid
first. There is silver plating on the threads to act as antiseize, if
you have a peroxide leak through a silver fitting then the fitting
ends up getting hot and the leak escalates itself to asking to speak
to the manager. Once you strip the silver antiseize off, then you need
to replace it with something else on assembly, like krytox.

Any use of any swage fitting over 3000 psi is a mistake. Go straight
from AN to cone and thread. Do not believe the marketing around medium
pressure swage fittings. When a 5000 psi fitting decides to dissociate
next to you, the best case is a startling.

Ben

On Fri, Mar 27, 2020 at 5:05 PM Rick Wills <willsrw@xxxxxxxxx 
<mailto:willsrw@xxxxxxxxx> > wrote:

Hi



Has anyone on the list used Swagelok compression fittings in service with 
LOX (3/4 or 1 in)?  I’ve used AN (37 deg flare) and NPT fittings 
successfully for LOX. NPT fittings are wrapped with PTFE tape.  My entire 
LOX side on my test stand is all AN expect for the NPT adapters used on 
the main LOX valve and LOX load valve.  Any LOX experience with any other 
brand of compression fittings (Parker, etc).   I’m looking at changing the 
stand plumbing and am considering Swagelok.  Check out our Facebook page 
https://www.facebook.com/midwestpropulsiongroup to see the stand in action.



The Army missile spec forbids NPT fittings.  Most likely reason is they 
could vibrate loose.    I’ve seem amateur liquid systems using NPT  
fittings successfully.  Any advice would be appreciated.  On my first test 
stand, I welded the NPT fittings together.  It worked but looked pretty 
bad.  An A&P I know suggested safety wiring the NPTs so they would come 
loose.  That is a lot of work.



I’m lucky.  My outbuilding is also my rocket workshop.  When I want to 
escape I run out back for a few hours.   Thanks and everyone take care.



Be Safe,



Rick Wills

Huber Heights, Ohio




Attachment: image001.jpg
Description:

Other related posts: