[AR] Re: Swagelok fittings acceptable for LOX?

  • From: David Gregory <david.c.gregory@xxxxxxxxx>
  • To: arocket@xxxxxxxxxxxxx
  • Date: Tue, 12 Jul 2016 07:39:02 -0700

Or buy them already cleaned from swagelok, if it fits your budget.

On Jul 12, 2016, at 4:11 AM, Robert Watzlavick <rocket@xxxxxxxxxxxxxx> wrote:

Swagelok fittings in stainless, brass, or aluminum are fine for LOX. Just be 
sure to clean all the pieces for oxygen use. 

-Bob

On Jul 12, 2016, at 00:08, Kyle Meeuwsen <meeuwsen.engr@xxxxxxxxx> wrote:

Hello All,

Quick question - Are swagelok fittings acceptable for cryogenic (LOX) 
application? Just making sure.. A quick check on the internet provided 
nothing.

Thank you all again for all of the help so far. 

Kyle Meeuwsen
Portland State Aerospace Society



Other related posts: