Is there a difference in using the Yor-Lok style vs the regular ferrule.

Edward

On Tue, Jul 12, 2016 at 11:38 AM, Jonathan Goff <jongoff@xxxxxxxxx> wrote:

We've also used them for vacuum cryo plumbing at Altius, where we needed
to pass LN2 into a reasonably high vacuum environment (10^-5 Torr), and so
far haven't had any problems with swagelok fittings when used correctly.

~Jon

On Tue, Jul 12, 2016 at 10:52 AM, Michael Clive <clive@xxxxxxxxxxx> wrote:

Used em for years in deep cryogenic applications, bubble tight at 6k
helium on half inch lines
On Jul 12, 2016 11:02 AM, "Kyle Meeuwsen" <meeuwsen.engr@xxxxxxxxx>
wrote:

Thank you very much!

Best,
Kyle

On Tue, Jul 12, 2016 at 7:39 AM, David Gregory <
david.c.gregory@xxxxxxxxx> wrote:

Or buy them already cleaned from swagelok, if it fits your budget.

On Jul 12, 2016, at 4:11 AM, Robert Watzlavick <rocket@xxxxxxxxxxxxxx>
wrote:

Swagelok fittings in stainless, brass, or aluminum are fine for LOX.
Just be sure to clean all the pieces for oxygen use.

-Bob

On Jul 12, 2016, at 00:08, Kyle Meeuwsen <meeuwsen.engr@xxxxxxxxx>
wrote:

Hello All,

Quick question - Are swagelok fittings acceptable for cryogenic
(LOX) application? Just making sure.. A quick check on the internet
provided nothing.

Thank you all again for all of the help so far.

Kyle Meeuwsen
Portland State Aerospace Society