[AR] Re: Swagelok fittings acceptable for LOX?

  • From: Kyle Meeuwsen <meeuwsen.engr@xxxxxxxxx>
  • To: arocket@xxxxxxxxxxxxx
  • Date: Tue, 12 Jul 2016 08:02:36 -0700

Thank you very much!

Best,
Kyle

On Tue, Jul 12, 2016 at 7:39 AM, David Gregory <david.c.gregory@xxxxxxxxx>
wrote:

Or buy them already cleaned from swagelok, if it fits your budget.

On Jul 12, 2016, at 4:11 AM, Robert Watzlavick <rocket@xxxxxxxxxxxxxx>
wrote:

Swagelok fittings in stainless, brass, or aluminum are fine for LOX.
Just be sure to clean all the pieces for oxygen use.

-Bob

On Jul 12, 2016, at 00:08, Kyle Meeuwsen <meeuwsen.engr@xxxxxxxxx>
wrote:

Hello All,

Quick question - Are swagelok fittings acceptable for cryogenic (LOX)
application? Just making sure.. A quick check on the internet provided
nothing.

Thank you all again for all of the help so far.

Kyle Meeuwsen
Portland State Aerospace Society




Other related posts: