You didn’t say what flow coefficient you need but: 
https://www.gemssensors.com/docs/default-source/resource-files/catalog-pages/catalog-j_a-series.pdf?Status=Master&sfvrsn=332d3538_2

On Oct 8, 2020, at 11:59 AM, William Claybaugh <wclaybaugh2@xxxxxxxxx> wrote:


Testing shows that the Lake Axial Solenoid valve in my pneumatic payload 
separation system is  leaking at 125 psia despite a 1000 psia rating (two 
valves tested, both leaked); the leak is through the valve and caused the 
latchup of the payload to the vehicle to fail within an average of four 
minutes. Additional testing on my vibe table showed latch failure in less 
than one minute in ten tests.

Can anyone suggest a solenoid valve good for at least 250 psia and unlikely 
to leak under vibration?

Alternative suggestions to using a solenoid valve are welcome.