[AR] Re: Vibration Tolerant Pneumatic Valve

  • From: Bruno Berger <bruno.berger@xxxxxx>
  • To: arocket@xxxxxxxxxxxxx
  • Date: Fri, 9 Oct 2020 07:57:13 +0200

Bill,
is the vibration randomly in any direction or mainly in one particular
direction? I had the same problem once and then I just oriented the
valve (respectively the plunger's orientation) perpendicular to the
vibration direction. That worked well, but might not suitable for you,
but I could imagine that your solid organ pipe is just axial.

As others suggested, a small ball valve would do the job as well:

https://www.dropbox.com/s/naxwxy9vnql15nm/N2O-Valve.jpg?dl=0

Bruno

"At that time [1909] the chief engineer was almost always the chief test pilot 
as well. That had the fortunate result of eliminating poor engineering early in 
aviation" (Igor Sikorsky)

-- 
Bruno Berger
IBB.ch engineering GmbH (LLC)
E-Mail:  bruno.berger@xxxxxx
PGP:     https://www.ibb.ch/Bruno.Berger.asc
S/MIME:  https://www.ibb.ch/Bruno.Berger.crt
WWW:     https://www.ibb.ch


Am 08.10.2020 um 19:58 schrieb William Claybaugh:

Testing shows that the Lake Axial Solenoid valve in my pneumatic
payload separation system isĀ  leaking at 125 psia despite a 1000 psia
rating (two valves tested, both leaked); the leak is through the valve
and caused the latchup of the payload to the vehicle to fail within an
average of four minutes. Additional testing on my vibe table showed
latch failure in less than one minute in ten tests.

Can anyone suggest a solenoid valve good for at least 250 psia and
unlikely to leak under vibration?

Alternative suggestions to using a solenoid valve are welcome.

Thanks,

Bill